当前位置:首页 - 新闻中心 - 企业动态高压压缩空气增压泵要怎么

高压压缩空气增压泵要怎么看它压力够不够?

发布时间:2020-04-17 10:15:47   发布人:http://www.sdjingtuo.com
  近日,气体增压泵厂家接到客户的售后响应,称根据他们近期车间员工反映的情况,在生产中出现不正常的低压空气压力,设备因低压空气压力过低而引起停机等问题。由于时间不固定,甚会出现短时中断,然后恢复,再中断等往复现象。今天,针对工程师咨询有关“高压压缩空气增压泵要怎么看它压力够不够”的问题,得到了您想要的答案,下面为您分享!
  Recently, the gas booster pump manufacturer received the customer's after-sales response, saying that according to the recent situation reported by their workshop staff, abnormal low-pressure air pressure appeared in the production, and the equipment was shut down due to low-pressure air pressure. Because the time is not fixed, even short-term interruption, and then recovery, and then interruption and so on. Today, the engineer asked about "how do you think the pressure of the high-pressure compressed air booster pump is enough", and got the answer you want. Let's share it for you!
气体增压泵
  1.初审可能由以下原因引起:
  1. The preliminary examination may be caused by the following reasons:
  1.气压计坏了。
  1. The barometer is broken.
  2.高压压缩空气之间的增压泵向储气罐管道破裂或接头泄漏。
  2. The booster pump between the high-pressure compressed air breaks or leaks to the pipeline of the air storage tank.
  3.气体和空气管道中有太多的沉淀物,堵塞了。
  3. There is too much sediment in the gas and air pipes, which is blocked.
  4.高压压缩空气增压泵排气阀门密封不严密,气动增压泵密封松动,造成空气泄漏。
  4. The exhaust valve of high-pressure compressed air booster pump is not sealed tightly, and the seal of pneumatic booster pump is loose, causing air leakage.
  5.气动增压泵泵体内部活塞和活塞环磨损过多而漏气。
  5. The internal piston and piston ring of the pneumatic booster pump are worn too much and air leaks.
  二、故障排除方法:
  2、 Troubleshooting:
  观察气压计,若指示压力不足,可让气动增压泵运转几分钟,压力仍不上升或上升缓慢;但当气动增压泵的排气口有强烈的排气反应时,说明气压表已损坏,应将气压表进行修理。
  Observe the barometer, if the indicated pressure is insufficient, let the pneumatic booster pump run for several minutes, and the pressure still does not rise or rises slowly; however, when there is a strong exhaust reaction at the exhaust port of the pneumatic booster pump, it indicates that the barometer is damaged, and the barometer should be repaired.
  2. 如上述试验无问题,则检查从高压压缩空气增压泵到储气罐及控制阀进口管的接头是否松动、断裂或泄漏。
  2. If there is no problem in the above test, check whether the joint from the high-pressure compressed air booster pump to the air tank and the inlet pipe of the control valve is loose, broken or leaking.
  3.如高压压缩空气增压泵未充气储气罐,则检查气、气管道内是否有过多污物堵塞。如果它被堵塞了,应该污垢。
  3. If the high-pressure compressed air booster pump is not inflated to the air tank, check whether there is too much dirt blocking in the air and gas pipes. If it is clogged, the dirt should be removed.
  4、经以上检查,如未发现故障,则应进一步检查高压压缩空气增压泵排气阀是否有泄漏,根据故障更换或修复损坏的部件。
  4. After the above inspection, if no fault is found, further check the exhaust valve of high-pressure compressed air booster pump for leakage, and replace or repair the damaged parts according to the fault.
  5. 检查调整卸荷阀安装方向是否与标示方向(箭头)一致。
  5. Check whether the installation direction of the unloading valve is consistent with the marked direction (arrow).
  以上是气体增压泵厂家为大家介绍的相关内容,想要了解更多内容,欢迎访问网站:http://www.sdjingtuo.com
  The above is the relevant content introduced by the gas booster pump manufacturer. For more information, please visit the website: http://www.sdjingtuo.com